Grid Overview
Grid specification: | |
---|---|
Grid number: | 101 |
Number of APDs: | 20 |
Grid information: | |
Arrival for irradiation: | 03. Aug 2017 |
Date of irradiation: | 10. Aug 2017 |
Irradiation temperature: | 20 °C |
Irradiation voltage: | individual voltage |
Irradiation dose: | 45 Gy |
Irradiation position: | 1 |
Shipped for annealing/analysis: | 23. Aug 2017 |
Annealing date: | none |
Annealing temperature: | none |
Annealing duration: | none |
Return for assembly: | none |
Operations: | Enter irradiation data • Enter annealing data • Enter shipment data |
Grid overview: | |
Slot 0: | 0810007923 (HV connected) |
Slot 1: | 0810007934 (HV connected) |
Slot 2: | 0810007924 (HV connected) |
Slot 3: | 0810007935 (HV connected) |
Slot 4: | 0810007925 (HV connected) |
Slot 5: | 0810007936 (HV connected) |
Slot 6: | 0810007927 (HV connected) |
Slot 7: | 0810007937 (HV connected) |
Slot 8: | 0810007928 (HV connected) |
Slot 9: | 0810007938 (HV connected) |
Slot 10: | 0810007929 (HV connection unknown) |
Slot 11: | 0810007939 (HV connected) |
Slot 12: | 0810007930 (HV connected) |
Slot 13: | 0810007940 (HV connected) |
Slot 14: | 0810007931 (HV connected) |
Slot 15: | 0810007943 (HV connected) |
Slot 16: | 0810007932 (HV connected) |
Slot 17: | 0810007944 (HV connected) |
Slot 18: | 0810007933 (HV connected) |
Slot 19: | 0810007945 (HV connected) |